For simple, fast & accurate COPD screening
The copd-6‚ identifies those at risk of COPD at the pre-symptomatic stage to allow early medical intervention and facilitate better clinical outcomes.
This pioneering device screens out those whose FEV1 is normal and who, therefore, do not have COPD without the risk of false COPD negatives, allowing spirometry resources to be focused on those most at risk.
- For the early detection of COPD - quickly, simply and accurately
- Identifies those at risk of COPD at the pre-symptomatic stage to allow early medical intervention and facilitate better clinical outcomes
- Screens out those whose FEV1 is normal, and who therefore do not have COPD, without the risk of false COPD negatives
- Facilitates case selection so that spirometry resources can be focused on those most likely to be diagnosed with COPD
- Monitors COPD patients using their number, the obstructive index, FEV1 as a percent of predicted
- Displays FEV1, FEV6, ratio and % predicted, obstructive index, COPD classification and lung age
- Built-in quality of blow indicator on a large, easy to read display
- Can be used with hygienic Vitalograph Bacterial Viral Filters (eco BVF)
- Displays the GOLD COPD classification (stage I - IV) to help recognise the need for a change in the patients management plan
- Requires only minimal instruction for use by non-respiratory specialists
Product: | Vitalograph copd-6 |
Model Number: | 4000 |
Part Number | 40200, 40450, 40350, 40850 |
Description | Vitalograph copd-6, Vitalograph copd-6 usb, Vitalograph copd-6 bluetooth, Vitalograph copd-6 serial |
Parameters Displayed | FEV1/FEV6/ratio and % predicted |
Quality of Blow Indicator: | Yes |
Obstructive Index: | Mild, Moderate, Severe (FEV1% predicted) |
COPD Classification: | Normal (not COPD); Stage I, II, III & IV (FEV1% predicted) |
Lung Age Indicator: | Yes |
Flow Impedance: | Better than 0.15 kPa/L/s at 14 L/s |
Sensor: | Stator rotor |
Operating Temperature Range: | 17 - 37°C |
Accuracy: | Better than +/- 3% |
Range: | 0 - 9.99 L BTPS |
Size: | 113 x 63 x 48mm |
Weight: | 55g net |
Display: | Custom Liquid Crystal Display |
Power: | AAA batteries |
Performance Standards: | ISO 26782:2009 ISO 23747:2007 ATS/ERS 2005 |
Safety Standards: | IEC 60601-1:2005 |
Medical Safety Standard: | Medical Devices 93/42/EEC (as amended) |
Designed and manufactured to following QA/GMP standards: | ISO 13485:2003 FDA 21CFR820 |