<  Terumo Safeed Extension Tube

Terumo Terufusion Syringe Pump TE-331

SKU: MED2280001

Market price: $2635.00. you save $239.55
9% less
 
$- Price Ex. GST
$+ Price inc. GST
*
Please, select all options.

$2395.45

Quantity:
Discount Price Breaks



Terumo Terufusion Syringe Pump TE-331

Ease of use and high performance are not mutually exclusive. That is what we prove with the Terumo syringe pumps.

In order to minimize the risk of ADES, the Terumo syringe pumps are equipped with several safety features. The risk of reading mistakes or misprogramming of the flow rate will be reduced thanks to the large, orange coloured decimal point and the difference in size between the digits and the decimal places. The pumps are also equipped with a unique user friendly and ergonomically designed dial to help eliminate mistakes whilst programming the settings. When the flow rate is set higher than 10 mL/h the pump will give a warning sound.

The syringe can no longer be wrongly placed thanks to the barrel detection function and the larger plunger clamps.

The pumps meet the safety requirements of EN 60601-1, EN 60601-2, EN 60601-1-4 and EN 60601-2-24.

All the syringe pumps can be used with 10, 20, 30 and 50 ml syringes from Terumo and other specified brands. The correctness of the flow rate is within 1% for mechanical accuracy and within 3% for accuracy including the syringe.

The durability or life span of the pumps are 6 years provided that the pumps are handled according to the conditions prescribed on the packaging and in the manual. The normal shelf life of the battery in the pump is 12 months.

Alarms available on TE-331 and TE-332: Occlusion (3 levels), Nearly empty, Syringe dislocated, Low Battery, Plunger/clutch disengaged, Infusion completion, AC/DC cable disconnection.

Specifications

  • Product Name: TERUFUSION Syringe Pump TE-331
  • Compatible Syringes 10, 20, 30 and 50 mL (TERUMO and specified brands)
  • Range of Flow Rate Setting:
    • 0.1-300 mL/h (for 10, 20 and 30 mL syringes)
    • 0.1-999 mL/h (for 50 mL syringes)
    • 0.1-1200 mL/h (special function for 50 mL syringes)
  • Flow Rate Display Change:
    • 0.1 mL/h steps (for settings from 0.1 to 99.9
    • mL/h) 1 mL/h steps (for settings from 100 to 999 mL/h)
  • Flow Rate Accuracy:
    • Mechanical Accuracy: ±1%
    • Accuracy including syringe: ± 3%
  • Occlusion Detection Pressure: Selectable from three levels. (Values are with use of TERUMO syringe)
    • [III]: 800 ± 200 mmHg max. (106.7 kPa ± 26.7 kPa)
    • [II]: 500 ± 100 mmHg max. (66.7 kPa ± 13.3 kPa)
    • [I]: 300 ± 100 mmHg max. (40 kPa ± 13.3 kPa)
    • Optional: 5 occlusion levels (100, 200, 300, 500 and 800 mmHg)
  • Priming (purge rate): 300 mL/h ~ 1200 mL/h (Depending on syringe size)
  • Alarms: Occlusion, Nearly empty, Low Battery, Plunger/Clutch disengaged, Syringe disengaged, AC/DC Cable disconnected. High flow warning when turning the dial over 10 mL/h (optional)
  • Special Functions: Functions are selectable via internal switches:
    • Delivery Limit setting:
      • 0.1 – 999.9 mL (in 0.1 mL steps)
      • When the limit is reached, an alarm will occur and the infusion will continue at KVO rate of 0.1 mL/h.
    • Nearly Empty alarm setting:
      • The time until the syringe is empty can be programmed. (from 3 to 60 min.)
    • Max. Flow Rate:
      • 1 – 1200 mL/h (in 1 mL steps)
    • Syringe Brand Confirmation
    • Memory function (last settings)
    • Changeable flow rate during infusion
  • Power Supply:
    • 100 to 240 VAC, 50/60 Hz
    • 12 to 15 VDC
    • Operable duration using internal battery NiMH:
    • Approx. 5 hours (using a new battery at flow rate of 5 mL/h and ambient temperature of 25°C, after charging at least 15 hours with the power off)
  • Classification (acc. to IEC 60601-1):
    • Class I and internally powered equipment, Type CF, Continuous operation, IPX4 (splashproof)
  • External Dimensions: 322 (W) x 114 (H) x 115 (D) mm
  • Weight: TE-331 ± 1.8 kg
  • External Communication and Nurse Call Connector: RS-232 or RS-485, Nurse call : 12 VDC, 1 A max.
Terumo
Shipping & Return policy.
The fees payable are calculated on size and destination of the order. We offer discounted shipping on multiple purchases which are combined automatically in checkout;- if you require pricing on multiple purchases please contact us prior to purchase with the items you require so that we can calculate a postal charge.
If we cannot ship an item to you, or there is a delay due to an item on backorder you will be notified by email or phone.

Delivery Times
Domestic Shipping (Within Australia)
Most items are in stock and shipment is usually within 24 - 48 hours of receiving cleared payment, you will be advised if the item is on backorder. Orders requiring customization may incur a further 24-48 hour delay in dispatch. Dispatches are Monday to Friday excluding Public Holidays. Domestic delivery within Australia is via our nominated courier service.

Faulty Items

Warranty / Returns within the first 14 days.

Please refer to the advertisement for details of the duration of the warranty on the product. Should you receive your items with the following faults we will happily offer replacement items subject to stock availability.

Product is Dead on Arrival
An incorrect item was shipped to you


If we do not have a replacement item a refund will be given.
If the above applies please contact us within 10 days of dispatch or 7 days of receipt of the item to arrange for it to be replaced.
Products must be returned to us within 14 calendar days of the issuance of the RMA (Return Material Authorization).
Configure-to-order, personalized or other customized products may not be returned for refund or exchanged under any circumstances unless such product is Dead on Arrival (see the section below for more detailed information on such Dead on Arrival products).
All products must be packed in the original packaging and include any accessories, manuals, documentation and registration that shipped with the product.
For DOA/Damaged Goods products a postal refund is offered to customers, but not to exceed the maximum of the amount paid at the time of placing the goods for the item to be returned to Medshop Australia.
Replacement of DOA products will be at our expense.

All returned goods will be checked by our service department prior to replacement. If no fault is found return will be at the customer's expense.

Warranty issues outside the first 14 days.

Warranty issues beyond the initial receipt. Please contact us with details of the problem; often these can be easily resolved through communication without the goods needing to be returned. Telephone support is provided to assist with any technical issues and minimalize on returns. All items returned during this time will be at customer's expense, return postal costs will be advised at the time of authorization of the return. Please ensure that any warranty documents are retained at time of purchase - certain manufacturers will not cover warranties without these documents being returned to them. A number of suppliers require the warranty item/claim to be made directly to them rather than through Medshop. In these instances you will be advised by our customer service team when a claim is made to return the item directly to the Australian distributor/manufacturer.

Unwanted Goods

If you have purchased the item and decide that you do not require it, we may offer a refund less a restocking fee of 20% on the cost of the item. Postal costs are not refundable.
Returned items in this category must be unused and in "as new"; and "saleable" condition with all original packaging and accessories returned.
Postage on the returned goods will be at Buyer's expense, it is advisable to arrange for the goods to be sent registered post or with a tracking number so that missing parcels can be traced. We will not accept COD returns.

Under exceptional circumstances we reserve the right to refuse return of goods.

Warranty Periods

Warranty periods as stated on the Medshop website are based on the Manufacturers warranty periods, terms and conditions. Terms of conditions differ per product and per manufacturer. Please see the manufactures website or contact a Medshop member of staff for clarifications.

All warranty claims should be made through Medshop unless otherwise stated on the product warranty supplied with the product.

Medshop will in certain instances service outside the warranty period, and warranty terms, this is case dependent and is left to the discretion of Medshop.

Warranty Referrals

Certain products and manufacturers require Medshop to refer all cases of warranty claims. These referrals are designed to ensure that claims are handled efficiently and by the most experienced service professionals.
Should a Medshop referral not be resolved in an acceptable manner please notify us so actions can be taken to ensure the correct levels of service are provided. Medshop prides itself on supporting customers.
<  Previous Product - Terumo Safeed Extension Tube