Welch Allyn Braun ThermoScan Pro4000 Ear Thermometer
- Improved thermometer accuracy and repeatability through a preheated probe tip and
sensor
- Probe cover detection system ensuresthe thermometers precise infrared
heat transfer for accurate temperatures
- Automatic probe cover eject button for quick and easy
disposal of used probe covers
- Easy-to-read LCD display
-
Welch Allyn and
Braun thermoscan technology is industry leading.
- 3 year limited warranty
Additional Information
Welch Allyn are world leaders in hand held diagnostic. The speed and accuracy you need for all types of patients
. This new model provides the speed and accuracy you need for all types of patients. The exclusive ExacTemp_ technology provides an active user feedback system to ensure proper positioning and improved accuracy.
Braun ThermoScan_ PRO 4000: Specifications
Displayed temperature
range: 68-108 _F (20-42.2 _C)
Operating ambient temperature range: 50-104 _F
(10-40 _C)
Display resolution: 0.1 _F or _C
Accuracy for displayed
temperature range: ±0.4 _F (95.9-107.6 _F) (35.5 _C-42 _C)
±0.5 _F (outside
this temperature range)
Long term storage ranges
Temperature: -4 _F to
122 _F (-20 _C to 50 _C)
Humidity: 95% non condensing
Shock: withstands
drop of 3 feet
Measurement time: 3-7 seconds
Automatic "power down": 60
seconds
Battery life: 6 months/1000 measurements
Battery type: 2 x MN
1500 or 1.5 V AA (LR6)
Thermometer dimension: 6? x 1.7? x 1.3? (152 mm x 44
mm x 33 mm)
Thermometer weight: 3.6 oz (100 g) without batteries
This
infrared thermometer meets the requirements established in ASTM Standard E
1965-98. Full responsibility for the conformance of the product to the standard
is assumed by Braun GmbH, 61476 Kronberg, Germany.
ASTM laboratory accuracy
requirements in the display range of 96.8 _F to 102.2 _F (36 _C to 39 _C) for
infrared thermometers is ± 0.4 _F (±0.2 _C), whereas for electronic
thermometers, the requirement per ASTM Standards E667-86 and E1112-86 is ±0.2 _F
(±0.1 _C).
A clinical summary is available upon request.
The Braun
ThermoScan thermometer has been proven to be safe. To ensure the best results,
please take the time to read this manual completely and keep it handy for future
reference. In the unlikely event you experience any difficulty using the Braun
ThermoScan thermometer, please make Medshop Australia your
first contact.
This equipment has been tested for potential
electromagnetic interference in accordance to IEC 601-1-2. These tests confirm
that the emissions generated by the Braun ThermoScan PRO 4000 were well below
the required limits. Thus, electromagnetic interference with other equipment is
not to be expected.