Spot Vital Signs Device 4200B
BP Only (includes Pulse Rate and MAP)
Welch Allyn Spot Vital Signs has made its mark in ambulatory and acute care settings for its accuracy, durability and cost-effectiveness. Now with updated features, the fully automated, multiparameter Spot Vital Signs has become the device of choice for frontline caregivers world-wide.
Hospital-grade equipment now offers enhanced clinical performance and quality:
- Fast and accurate - completes BP, pulse rate, temperature, and SpO2 in approximately 30 seconds
- Multiparameter and modular so you can select precisely the vital signs you need
- Optional Masimo or Nellcor pulse oximetry
- Optional SureTemp thermometry
- IR connectivity to interface with computerised patient records
- Portable - carry it, wheel it, or mount it
- Big, bright, easy-to-read LCD screen
- Offers you one of the lowest priced multiparameter instruments on the market
- Fully upgradeable to meet your changing needs
- Intergrated long-life battery enhances portability and continuous operation
- Intuitive design and training materials provide concise, easy training for your staff
Specifications
Noninvasive Blood Pressure (NIBP)
- Cuff Pressure Range - 0 to 300 mmHg
- Initial Cuff Inflation - 160 mmHg (adjustable)
- Systolic Range - 60 to 250 mmHg
- Diastolic Range - 30 to 160 mmHg
- Mean Arterial Pressure Range - 40 to 190 mmHg
- Blood Pressure Accuracy - Blood pressure meets or exceeds SP10:1992 AAMI standards
- Blood Pressure Determination Time - 20-45 seconds typical
- Overpressure Cutoff - 315 mmHg +/- 15 mmHg
- Pulse Rate Range (using BP determination) - 40 to 200 bpm
- Pulse Rate Accuracy (using BP determination) +/- 5%
Temperature
- Measurement Range - 30 to 43 degree celcius
- Calibration Accuracy +/- 0.1 degree celcius (monitor mode)
- Determination Time - Oral - Approximately 4 seconds / Axillary - Approximately 10 seconds / Rectal - Approximately 15 seconds
- Probe - Oral/Axillary - Blue cap / Rectal - Red cap
SpO2
- Performance Measurement Range - 70% to 100%
- Pulse Rate Range - 25 to 240 bpm
- SpO2 Accuracy - Masimo: +/- 2 digits / Nellcor: +/- 3 digits
- Pulse Rate Accuracy - Masimo: +/- 3 digits / Nellcor: +/- 3 digits
Mechanical
- Dimensions - Height: 24.6 cm / Length: 14.5 cm / Depth: 12 cm
- Weight - 2.1kg
Electrical
- AC Power Supply - 7.2 V DC at 1.0 A, Rechargeable sealed lead acid internal battery
- Battery Recharge Time - 90% to 100% after 12 hours. Simultaneously operates device and charges battery when AC power adapter is plugged in
- Operating Time - A fully charged battery supports 150 typical blood pressure determinations at 7-minute intervals
Environmental
Operating Temperature - 10 to 40 degree ceclius
Operating Relative Humidity - 15% to 90% (noncondensing)
Operating Altitude - minus 170 m to +4,877 m
Storage Temperature - minus 20 to 50 degree celius
Storage Humdity- 15% to 90% (noncondensing)
EMC Standard - IEC/EN 60601-1-2
Two year warranty on parts and labour